Specifications
∗
C0914
Step Check Item Result Action
1
Slide out the 2nd Drawer and slide it back
in. Does the 2nd Drawer Lift-Up Motor M24
rotate?
YES
•
To Step 3.
2
When the 2nd Drawer is slid in, does the
voltage across PJ17F-3 (Metric Areas) or
PJ16F-3 (Inch Areas) on PWB- F and GND
change from DC0V to DC24V and then
change to DC0V again?
YES
•
Change M24.
NO
•
Change PWB-F or PWB-A.
3
While M24 is rotating, does the voltage
across PJ12F-5 (Metric Areas) or PJ14F-4
(Inch Areas) on PWB-F and GND change in
the range DC0V to DC5V?
YES
•
Change PWB-F or PWB-A.
NO
•
Check the inside of the Lift-Up
Motor Assy.
•
Change PC57.
∗
C0924
Step Check Item Result Action
1
Slide out the 1st Drawer and slide it back in.
Does the 1st Drawer Lift-Up Motor M23
rotate?
YES
•
To Step 3.
2
When the 1st Drawer is slid in, does the
voltage across PJ17F-1 (Metric Areas) or
PJ16F-1 (Inch Areas) on PWB- F and GND
change from DC0V to DC24V and then
change to DC0V again?
YES
•
Change M23.
NO
•
Change PWB-F or PWB-A.
3
While M23 is rotating, does the voltage
across PJ12F-2 (Metric Areas) or PJ14F-3
(Inch Areas) on PWB-F and GND change in
the range DC0V to DC5V?
YES
•
Change PWB-F or PWB-A.
NO
•
Check the inside of the Lift-Up
Motor Assy.
•
Change PC56.
T-98