Specifications
∗
C0910
Step Check Item Result Action
1
Slide out the 2nd Drawer and check the 2nd
Drawer Lift-Up Sensor PC15 as described
below:
1) Select "IC Port Data Check".
2) <Metric Areas>
Is the data of PE3 on PWB-F (3MJ)
(IC2F) " "?
(See the 5/8 Screen on T-7.)
<Inch Areas>
Is the data of PE3 on PWB-F (3MC)
(IC2F) " "?
(See the 6/8 Screen on T-7.)
NO
•
Check the Paper Take-Up Roll
Assy.
3) Slide the 2nd Drawer back in to
complete lift-up. (PC15: blocked).
4) Select "IC Port Data Check" again.
<Metric Areas>
Has the data of PE3 on PWB-F (3MJ)
(IC2F) changed from " " to " "?
<Inch Areas>
Has the data of PE3 on PWB-F (3MC)
(IC2F) changed from " " to " "?
YES
•
Change PWB-F or PWB-A.
NO
•
Change PC15.
∗
C0920
Step Check Item Result Action
1
Slide out the 1st Drawer and check the 1st
Drawer Lift-Up Sensor PC14 as described
below:
1) Select "IC Port Data Check".
2) <Metric Areas>
Is the data of PA3 on PWB-F (3MJ)
(IC2F) " "?
(See the 5/8 Screen on T-7.)
<Inch Areas>
Is the data of PA3 on PWB-F (3MC)
(IC2F) " "?
(See the 6/8 Screen on T-7.)
NO
•
Check the Paper Take-Up Roll
Assy.
3) Slide the 1st Drawer back in to complete
lift-up. (PC14: blocked).
4) Select "IC Port Data Check" again.
<Metric Areas>
Has the data of PA3 on PWB-F (3MJ)
(IC2F) changed from " " to " "?
<Inch Areas>
Has the data of PA3 on PWB-F (3MC)
(IC2F) changed from " " to " "?
YES
•
Change PWB-F or PWB-A.
NO
•
Change PC14.
H
H
H
H
L
L
H
H
H
H
L
L
T-97