Specifications

C0600, C0601
Step Check Item Result Action
1 Is PJ6J securely plugged into PWB-J? NO
Plug it in securely.
2
When the Power Switch is turned ON, is the
voltage across PJ6J-6 on PWB-J and GND
DC5V?
NO
Check the DC5V line.
3 Is C0600 being displayed? YES
Change M11.
4 Is C0601 being displayed? YES
Change PWB-J.
C0650
Step Check Item Result Action
1
Is PJ5J securely plugged into PWB-J and
PJ43 into PC1?
NO
Plug them in securely.
2
Is the Light Blocking Plate installed properly? YES
Change PC1.
NO
Reinstall.
C0660
Step Check Item Result Action
1
With the Power Switch OFF, do you feel an
overload when you move the Scanner
manually?
YES
Correct or change the Cables
or part being overloaded.
C06F0 to C06F7
Step Check Item Result Action
1
Is PJ12AB securely plugged into PWB-A
and PJ2J into PWB-J?
YES
Change PWB-A or PWB-J.
NO
Plug them in securely.
T-92