Specifications
∗
C0600, C0601
Step Check Item Result Action
1 Is PJ6J securely plugged into PWB-J? NO
•
Plug it in securely.
2
When the Power Switch is turned ON, is the
voltage across PJ6J-6 on PWB-J and GND
DC5V?
NO
•
Check the DC5V line.
3 Is C0600 being displayed? YES
•
Change M11.
4 Is C0601 being displayed? YES
•
Change PWB-J.
∗
C0650
Step Check Item Result Action
1
Is PJ5J securely plugged into PWB-J and
PJ43 into PC1?
NO
•
Plug them in securely.
2
Is the Light Blocking Plate installed properly? YES
•
Change PC1.
NO
•
Reinstall.
∗
C0660
Step Check Item Result Action
1
With the Power Switch OFF, do you feel an
overload when you move the Scanner
manually?
YES
•
Correct or change the Cables
or part being overloaded.
∗
C06F0 to C06F7
Step Check Item Result Action
1
Is PJ12AB securely plugged into PWB-A
and PJ2J into PWB-J?
YES
•
Change PWB-A or PWB-J.
NO
•
Plug them in securely.
T-92