Specifications

The procedures for C0100 and C0110 are the same. The parts for C0110 are indicated in the
parentheses.
Step Check Item Result Action
1
Is the Cleaner Holder at a stop in the home
position? (In the back part of the Corona)
YES
To Step 4.
2
Check PC54 (PC55) as described below:
 
1) Select "IC Port Data Check".
2) Is the data of BPB4 (BPB3) on PWB-A
(IC5A) " "? (See the 2/8 screen on T-7.) NO
Check the operation of the
Actuator or change PC54
(PC55).
3
When the Screw Shaft is turned by hand,
does the Cleaner Holder move smoothly? YES
Change PWB-P1 (PWB-P2). If
the malfunction recurs, change
PWB-A.
NO
Check the Stabilizing Plate for
burrs, the Screw for
deformation, and the Gear of
M21 (M22).
4
Check PC54 (PC55) as described below:
 
1) Select "IC Port Data Check".
2) Is the data of BPB4 (BPB3) on PWB-A
(IC5A) " "? (See the 2/8 screen on T-7.)
YES
Check the Stabilizing Plate for
burrs, the Screw for
deformation, and the Gear of
M21 (M22).
Change PWB-P1 (PWB-P2). If
the malfunction recurs, change
PWB-A or M21 (M22).
NO
Check the operation of the
Actuator or change PC54
(PC55).
H
H
T-81