Specifications

<PC Drum Drive Control>
M5 is energized and deenergized by the output from pin 52 of IC5A on
Master Board PWB-A.
= M5 Energization Timing =
M5 is energized at different timings depending on which drawer the paper is
fed from. Timer value T1, which is the period between the press of the Start
Key and the energization of M5, varies with the paper source as listed
below. This ensures that the PC Drum turns for a given period of time for
each copy cycle regardless of the paper source.
Paper Source T1
1st and 2nd Drawer 5msec
3rd Drawer 290msec
Multi Bypass Table 600msec
= M5 Deenergization Timing =
M5 is deenergized approx. 1,250 msec. after Scanner Control Processor
Board PWB-J has output a SCEND signal.
1075C01MAA
M-26