Specifications
Code Description Detection Timing and Sensor Layout
C0FE1 Original Size Detecting
Sensor
➊ failure
C0FE2 Original Size Detecting
Sensor
➋ failure
C0FE3 Original Size Detecting
Sensors
➊ and ➋ failure
C0FE4 Original Size Detecting
Sensor
➌ failure
C0FE5 Original Size Detecting
Sensors
➊ and ➌ failure
C0FE6 Original Size Detecting
Sensors
➋ and ➌ failure
C0FE7 Original Size Detecting
Sensors
➊
,
➋
, and
➌
failure
C0FE8 Original Size Detecting
Sensor
➍ failure
C0FE9 Original Size Detecting
Sensors
➊ and ➍ failure
C0FEA Original Size Detecting
Sensors
➋ and ➍ failure
C0FEB Original Size Detecting
Sensors
➊, ➋, and ➍ failure
C0FEC Original Size Detecting
Sensors
➌and ➍ failure
C0FED Original Size Detecting
Sensors
➊, ➌, and ➍ failure
C0FEE Original Size Detecting
Sensors
➋, ➌, and ➍ failure
C0FEF Original Size Detecting
Sensors
➊, ➋, ➌, and ➍
failure
Original Size Detecting Board
∗
<Detection Timing>
After having read the output data from UN3 to UN7,
UN2 determines that there is a failure.
<Sensor Layout>
Metric Areas
•
➊: UN5, ➋: UN4, ➌: UN3 (option),
➍: UN6, ➎: UN7 (option)
∗
UN3 and UN7 are standard for Hong Kong area.
•
A to E: Sensor locations
Inch Areas
•
➊: UN5 (option), ➋: UN4,
➌: UN3 (option), ➍: UN6
A
➊
B
C
➋
E
➌
D
➎
B
➍
A
A
➊
B
C
➋
E
➌
D
➍
A
T-63