Specifications
<During prescan>
•
When the Scanner is at other than the home position,
the SHOME signal does not go LOW 5 seconds after
the Power Switch has been turned ON.
•
The SHOME signal does not go LOW 5 seconds after
the SCEND signal has gone from LOW to HIGH.
<During a copy cycle>
•
When the Scanner is at other than the home position,
the SHOME signal does not go LOW 7 seconds after
the SCAN signal has gone LOW.
•
The SHOME signal does not go LOW 5 seconds after
the SCEND signal has gone from LOW to HIGH.
C06
∗∗
(Optical Section malfunctions)
∗
Code Description Detection Timing
C06F0 SHOME signal failure
(SHOME does not go
LOW)
C06F1 SHOME signal failure
(SHOME does not go
HIGH)
The SHOME signal does not go HIGH 7 seconds after it
has gone LOW.
C06F2 BASE signal failure
(BASE does not go
LOW)
The BASE signal does not go LOW 5 seconds after the
SHOME signal has gone HIGH.
C06F3 BASE signal failure
(BASE does not go
HIGH)
C06F4 TRON signal failure
(TRON does not go
LOW)
C06F5 TRON signal failure
(TRON does not go
HIGH)
C06F6 SCEND signal failure
(SCEND does not go
LOW)
C06F7 SCEND signal failure
(SCEND does not go
HIGH)
The SCEND signal does not go HIGH 5 second after it
has gone LOW.
<During prescan>
The SCEND signal does not go LOW 5 second after
the TRON signal has gone HIGH.
<During a copy cycle>
The SCEND signal does not go LOW 5 seconds after
the SHOME signal has gone HIGH.
<During prescan>
The BASE signal does not go HIGH 5 second after the
TRON signal has gone LOW.
<During prescan>
The TRON signal does not go HIGH 5 second after the
BASE signal has gone HIGH.
<During prescan>
The TRON signal does not go LOW 5 seconds after
the BASE signal has gone LOW.
<During a copy cycle>
The TRON signal does not go LOW 5 seconds after
the SHOME signal has gone HIGH.
T-47