C06
∗∗
(Optical Section malfunctions)
∗
Code Description Detection Timing
C0601 SCP Board PWB-J
malfunction
With no encoder pulses input to PWB-J for 100 to 130
msec. while M11 is turning, the Forward/Backward
Rotation signal from PWB-J goes from LOW to HIGH, or
vice versa, when an attempt is made to turn M11
backward.
C0610 Lens X-direction motion
failure
The output from the Lens X Direction Reference Position
Sensor PC2 does not go from HIGH to LOW or from LOW
to HIGH a given period of time after the Lens X-Direction
Drive Motor M12 has started.
C0611 Lens Y-direction motion
failure
The output from the Lens Y Direction Reference Position
Sensor PC3 does not go from HIGH to LOW or from LOW
to HIGH a given period of time after the Lens Y-Direction
Drive Motor M13 has started.
C0650 Scanner Reference
Position Sensor PC1
malfunction
C0660 Scanner load failure The Scan Motor M11 does not switch from acceleration to
constant speed from when the SHOME signal goes LOW
until when a LOW TRON signal is detected.
<At the start of the Scanner’s scan motion>
PC1 is not unblocked ( ) after a given period of time
has elapsed.
<At the end of the Scanner’s return motion>
PC1 is not blocked ( ) after a given period of time
has elapsed.
H
L
M11
H
L
H
L
1075T141CA
ON
OFF
Encoder Pulse
100~130 msec
Forward rotation
Signal
Backward rotation
Signal
M11
1075T142CA
Acceleration
Constant speed
T-46