Specifications
7 sec
M21
H
L
1075T131CA
Forward rotation
OFF
PC54
20 sec
OFF
H
L
1075T132CA
M21
Backward rotation
PC54
2 sec
M14
PC30
H
L
1075T130CA
ON
OFF
10 sec
M14
H
L
1075T129CA
ON
OFF
PC30
C00
∗∗
(Drive system malfunctions)
* Code Description Detection Timing
The output from PC30 does not go Low within 10 seconds
after it has gone HIGH following the energization of M14.
C0071 Main Hopper Toner
Replenishing Motor M14
turning at abnormal
timing
The PC30 output goes HIGH 2 seconds after M14 has
been deenergized.
C0072 Sub Hopper Toner
Replenishing Motor
M15’s failure to turn
When the current toner-to-carrier ratio is 2% lower than
the "T/C control level set by AIDC Sensor control" and the
Add Toner Indicator is not lit on the control panel, a toner
replenishing sequence is carried out (M15 is turned); the
toner- to-carrier ratio does not increase by 2% within 220
seconds.
C0080 Synchronizing Motor M4
turning at abnormal
timing
The Watchdog Pulse signal from the Synchronizing Motor
Control Board remains unchanged for 5 seconds.
C01
∗∗
(PC Drum Charge, Image Transfer/Paper Separator Corona cleaning malfunctions)
* Code Description Detection Timing
C0100 PC Drum Charge Wire
Cleaning Motor M21’s
failure to turn
The output from the Drum Wire Cleaner Home Position
Sensor PC54 does not go HIGH 7 seconds after M21 has
started forward rotation (cleaning).
The output from PC54 does not go LOW 20 seconds after
M21 has started backward rotation (home position return).
T-39