Specifications

10 sec
M29
Power Supply Unit
Cooling Fan Motor
Lock Signal
H
L
1075T127CC
ON
OFF
5 sec
M14
H
L
1075T128CA
ON
OFF
PC30
20 sec
M8
Fusing Ventilation
Fan Motor
Lock Signal
H
L
1075T125CD
ON
OFF
2 sec
M29
Power Supply Unit
Cooling Fan Motor
Lock Signal
ON
OFF
H
L
1075T126CB
10 sec
M19
Ventilation Fan Motor
Lock Signal
H
L
1075T184CB
ON
OFF
C00
∗∗
(Drive system malfunctions)
* Code Description Detection Timing
C004d Fusing Unit Ventilation
Fan Motor M8 turning at
abnormal timing
Ventilation Fan Motor
M19 turning at abnormal
timing
<M8>
The Fusing Ventilation Fan Motor Lock signal remains
LOW for a continuous 20-second period after M8 has been
deenergized.
<M19>
The Ventilation Fan Motor Lock signal remains LOW for a
continuous 10-second period after M19 has been
deenergized.
C004E Power Supply Unit
Cooling Fan Motor
M29s failure to turn
The Power Supply Unit Cooling Fan Motor Lock signal
remains HIGH for a continuous 2-second period after M29
has been energized.
C004F Power Supply Unit
Cooling Fan Motor M29
turning at abnormal
timing
The Power Supply Unit Cooling Fan Motor Lock signal
remains LOW for a continuous 10-second period after M29
has been deenergized.
C0070 Main Hopper Toner
Replenishing Motor
M14s failure to turn
The output from the Toner Bottle Home Position Sensor
PC30 does not go HIGH within 5 seconds after M14 has
been energized.
T-38