Specifications

<Duplex Unit Entry Misfeed Clearing Procedure>
Symptom Step Check Item Result Action
The leading
edge of the
paper is at a
stop inside
the Duplex
Unit.
1
Is the Paper Guide Mylar dirty or
deformed?
YES
Clean or change the
Mylar.
2
Check the Duplex Unit Paper Entry
Sensor PC38.

1)
2)
Remove the misfed paper.
Select "IC Port Data Check".
3) Is the data of PC1 on PWB-G
(IC1G) " "?
(See the 6/8 screen on T-7.)
NO
Check the operation of
the Actuator.
4) Operate the Actuator to block
PC38.

5) Return to the "I/O Check" menu
screen and select "IC Port Data
Check" again. Has the data of
PC1 changed from " " to " "?
NO
Change PC38.
3
Check the Duplex Unit Gate
Switching Solenoid SL2.

1)
2)
Remove the misfed paper and
reset the misfeed.
Select "IC Port Data Check".
3) Is the data of PH1 on PWB-G
(IC1G) "1"?
(See the 7/8 screen on T-7.)
NO
Change PWB-G or
PWB-A.
4) By pressing the "Change" key
to change the data from "1" to
"0", does SL2 operate? (Make
sure that SL2 makes a sound.)
YES
Change PWB-G or
PWB-A.
NO
Change SL2 or adjust its
stroke.
Paper is at a
stop in the
Entry Section.
1
Check the Duplex Unit Paper
Empty Sensor PC41.

1)
2)
Remove the misfed paper.
Select "IC Port Data Check".
3) Is the data of PC2 on PWB-G
(IC1G) " "?
(See the 6/8 screen on T-7.)
NO
Check the operation of
the Actuator.
4) Operate the Actuator to block
PC41.

5) Return to the "I/O Check" menu
screen and select "IC Port Data
Check" again. Has the data of
PC2 changed from " " to " "?
YES
Change PWB-G or
PWB-A.
NO
Change PC41.
H
H
L
H
H
L
T-31