Specifications
<Duplex Unit Vertical Transport Misfeed Clearing Procedure>
Symptom Step Check Item Result Action
•
Paper is at a
stop in the
Exit Section.
1
Check the operation of the
Exit/Duplex Switching Solenoid SL1.
1)
2)
Remove the misfed paper and
reset the misfeed.
Select "IC Port Data Check".
3) Is the data of BPB1 on PWB-A
(IC4A) "1"?
(See the 2/8 screen on T-7.)
NO
Change PWB-A.
4) By pressing the "Change" key
to change the data from "1" to
"0", does SL1 operate? (Make
sure that SL1 makes a sound.)
YES
Proceed to Step 2, or
change SL1 or adjust its
stroke.
5) By making a "Board Check", is
the malfunction code "C0321"
displayed?
YES Change PWB-A.
NO
Change SL1.
2
Are the Exit/Duplex Switching Plate
and Upper and Lower Guide Plates
dirty or deformed?
NO
Clean or change the
Plates.
•
Paper is at a
stop in the
Vertical
Transport
Section of the
Duplex Unit.
1
Run the Duplex Unit Drive Motor
M7 and check the operations of the
Duplex Unit Vertical Transport Roll
and Duplex Unit Drive Connection.
1)
2)
3)
Open the left door.
Select "IC Port Data Check".
Press the "Change" key to
change the data of PB3 on
PWB-G (IC1G) from "1" to "0".
(See the 6/8 screen on T-7.)
4) Do the Duplex Unit Vertical
Transport Roll and Duplex Unit
Drive Connection operate
properly?
NO
Check the gears, rollers
and belts.
2
Check the Turnover Feed Sensor
PC37.
1)
2)
Remove the misfed paper.
Select "IC Port Data Check".
3) Is the data of APB5 on PWB-A
(IC5A) " "?
(See the 2/8 screen on T-7.)
NO
Check the operation of
the Actuator.
4) Operate the Actuator to block
PC37.
5) Return to the "I/O Check" menu
screen and select "IC Port Data
Check" again. Has the data of
APB5 changed from " " to
" "?
YES Change PWB-A.
NO
Change PC37.
H
H
L
T-29