Specifications

Symptom Step Check Item Result Action
Paper is at a
stop near the
PC Drum.
1
Is the Pre-Image Transfer Guide
Plate deformed or dirty?
YES
Clean, correct or change
the Guide Plate.
2
Are the Image Transfer/Paper
Separator Corona Wires dirty or
deteriorated?
YES
Clean or change the
Corona Wires.
3
Is the Paper Guide above the
Paper Separator Corona dirty or
deformed?
YES
Clean or change the
Paper Guide.
4
Are the Synchronizing Rollers
deformed, worn, or dirty with paper
dust?
YES
Clean or change the
Synchronizing Rollers.
5
Check the Paper Separator Corona
Remote signal from PWB-A.
Does the malfunction code
"C034A" appear when a "Board
Check" is made?
YES Change PWB-A.
NO
Change the Image
Transfer/Paper
Separator Coronas Unit
or the High Voltage Unit
HV2.
Paper is
wedged at the
Drum Paper
Separator
Fingers.
1
Are the Drum Paper Separator
Fingers dirty or deformed?
YES
Clean or change the
Separator Fingers.
2
Check the operation of the
Separator Fingers Solenoid SL6.

1)
2)
Remove the misfed paper and
reset the misfeed.
Select "IC Port Data Check".
3) Is the data of BPB2 on PWB-A
(IC4A) "1".
(See the 2/8 screen on T-7. )
NO
Change PWB-A.
4) By pressing the "Change" key
to change the data from "1" to
"0", does SL6 operate? (Check
that SL6 makes a sound.)
YES
Adjust the solenoid
stroke.
5) By making a "Board Check", is
the malfunction code "C031F"
displayed?
YES Change PWB-A.
NO
Change SL6.
T-21