Specifications

Book B Scan Registration (A-6)
Adjust Book Scan B by changing the engagement timing of the Synchronizing Roller.
Setting Description Initial Setting
45 5 pulses
46 4 pulses
47 3 pulses
48 2 pulses
49 1 pulse
50 ±0
Setting Description Initial Setting
51 +1 pulse
52 +2 pulses
53 +3 pulses
54 +4 pulses
55 +5 pulses
Setting Description Initial Setting
40 10 pulses
41 9 pulses
42 8 pulses
43 7 pulses
44 6 pulses
45 5 pulses
46 4 pulses
47 3 pulses
48 2 pulses
49 1 pulse
50 ±0
Setting Description Initial Setting
51 +1 pulse
52 +2 pulses
53 +3 pulses
54 +4 pulses
55 +5 pulses
56 +6 pulses
57 +7 pulses
58 +8 pulses
59 +9 pulses
60 +10 pulses
Lens Position Enlargement Registration (A-11)
Adjust the leading edge for a enlargement copy by changing the engagement timing of the
Synchronizing Roller.
Note: Increments: Approx. 0.8 mm/1 pulse
Note: Increments: Approx. 0.4 mm/1 pulse
Lens Position Adjust (A-10)
Corrects the optical center of the lens (to center the copy image) by moving the lens position.
Setting Description Initial Setting
40 10 pulses
41 9 pulses
42 8 pulses
43 7 pulses
44 6 pulses
45 5 pulses
46 4 pulses
47 3 pulses
48 2 pulses
49 1 pulse
50 ±0
Setting Description Initial Setting
51 +1 pulse
52 +2 pulses
53 +3 pulses
54 +4 pulses
55 +5 pulses
56 +6 pulses
57 +7 pulses
58 +8 pulses
59 +9 pulses
60 +10 pulses
S-68