Specifications

Lens Position Full Size Registration (A-4)
Adjusts the leading edge for a full size copy by changing the engagement timing of the
Synchronizing Roller.
Setting Description Initial Setting
40 10 pulses
41 9 pulses
42 8 pulses
43 7 pulses
44 6 pulses
45 5 pulses
46 4 pulses
47 3 pulses
48 2 pulses
49 1 pulse
50 ±0
Setting Description Initial Setting
51 +1 pulse
52 +2 pulses
53 +3 pulses
54 +4 pulses
55 +5 pulses
56 +6 pulses
57 +7 pulses
58 +8 pulses
59 +9 pulses
60 +10 pulses
Note: Increments: Approx. 0.4 mm/1 pulse
S-66