Specifications

Loop Adjust (Man/LCT)
Used to adjust the loop length (before the Synchronizing Roller) of the paper fed manually or
from the paper feed option.
Code Loop Length Initial Setting
47 Approx. 4 mm
48 Approx. 6 mm
49 Approx. 8 mm
50 Approx. 10 mm
Code Loop Length Initial Setting
51 Approx. 12 mm
52 Approx. 14 mm
53 Approx. 16 mm
Exp. Lamp Manual Adj.
Used to make fine-adjustment of the Lamp voltage in the Manual Exposure mode. When an
optimum manual exposure level cannot be achieved by the execution of the "F5" function mode
after the replacement of the PC Drum, etc., adjust the Exposure Lamp voltage in the range of 6
to +6V.
Code
Variable Voltage
Value
Initial Setting
44 6V
45 5V
46 4V
47 3V
48 2V
49 1V
50 0V
Code
Variable Voltage
Value
Initial Setting
51 +1V
52 +2V
53 +3V
54 +4V
55 +5V
56 +6V
Note: After the setting of this mode has been changed, the "F5" mode must be executed.
T/C Control Level Adj.
Used to adjust the T/C control Level set by the AIDC Sensor Control.
This adjustment affects the grid voltage which produces the solid black pattern, which in turn
determines the setting of the AIDC Sensor Control.
Code
Grid Voltage
Correction
Initial Setting
47 Vg 0V
48 Vg 15V
49 Vg 30V
50 Vg 45V
Code
Grid Voltage
Correction
Initial Setting
51 Vg 60V
52 Vg 75V
53 Vg 90V
54 Vg 105V
Note : Code 50 47 Toner Density is increased.
Code 50 54 Toner Density is decreased.
S-32