Specifications
● F4 (HV Separator)
Used to confirm the output of the High Voltage Unit (HV) for the Paper Separator Corona. (For
factory setting)
<Operation time>
•
This function runs for 60 seconds.
•
This function runs until the Stop Key is pressed.
● F5 (Optimum & AE)
Used to make Vg level adjustment, manual optimum exposure adjustment, and automatic AE
Sensor optimum exposure adjustment.
<Operation time>
•
This function runs for 30 seconds.
•
This function runs until the Stop Key is pressed.
● F6 (Edit Ref. Adj)
Used to adjust the edit position according to the pattern output by the Image Erase Lamp.
<Operation time>
•
This function runs for one copy cycle.
● F7 (Orig. Sensor)
Used to automatically adjust the Original Size Detecting Sensor.
<Operation time>
•
This function continues until the adjustment ends.
● F8 (ATDC Adjust)
This function agitates the developer to automatically adjust the ATDC Sensor level.
<Operation time>
•
This function runs for 3 minutes.
•
This function runs until the Stop Key is pressed.
● FD (Paper Width)
Used to automatically adjust the center registration for manual feed.
<Operation time>
•
This function continues until the adjustment is complete.
● FE (Blade Priming)
•
Used when setting up a new machine or replacing either the Drum or Cleaning Blade.
•
This function primes the Cleaning Blade to ensure a good, smooth fit between Blade and Drum,
and to prevent warping of the Blade.
<Operation time>
•
This function runs for 45 seconds.
•
This function runs until the Stop Key is pressed.
S-25