Specifications
5-3. Settings in the Tech. Rep. Mode
1. Function
•
Used to adjust/confirm various Tech. Rep. functions.
1075S003CB
Function
F1 PaperPassage
Menu
F7 Orig. Sensor
F2 Drum/Trans F8 ATDC Adiust
F3 Exp. Lamp
F4 HV Separator
F5 Optimum & AE
F6 Edit Ref. Adj
FD Paper Width
FE Blade Priming
1-1. Function mode setting procedure
<Setting Procedure>
1. Select "Function".
2. Select the function mode to be adjusted/confirmed.
3. Press the Start Key to start the operation of the corresponding mode.
4. Press the Stop Key to stop the operation.
1-2. Settings in the Function mode
● F1 (Paper Passage)
This test can be initiated without having to wait for warm-up to complete.
<Operation time>
•
This test continues until the Drawer or port selected for use runs out of paper.
•
This test continues until the Stop Key is pressed.
● F2 (Drum/Trans)
Used to confirm the output of the High Voltage Unit (HV) for Drum Charge/Image Transfer
Coronas. (For factory setting)
<Operation time>
•
This function runs for 30 seconds.
•
This function runs until the Stop Key is pressed.
● F3 (Exp. Lamp)
Used to confirm that the Exposure Lamp is lit.
<Operation time>
•
This test runs for 30 seconds.
•
This test runs until the Stop Key is pressed.
S-24