Specifications

1075D087AA
4. Remove two screws from the lower guide frame and
slide out the Pre-Image Transfer Erase Lamp.
1. Remove the PC Drum Charge Corona.
2. Unlock two PC Drum Lock Levers and remove or
replace the PC Drum.
1. Remove the PC Drum and Cleaning Unit.
2. Unplug one connector.
3. Remove one screw and the cord clamp.
1. Remove the PC Drum.
2. Unplug two connectors and remove the Main Erase
Lamp holder.
1075D085AA
1. Remove the PC Drum.
2. Blow all foreign matter off the Pre-Image Transfer
Erase Lamp with a blower brush.
If the lamp is seriously contaminated, wipe its surface
clean of dirt with a soft cloth.
(6) Cleaning of the Pre-Image Transfer Erase Lamp
(7) Removal of the Pre-Image Transfer Erase Lamp
(8) Removal of the Main Erase Lamp
(5) Replacement of the PC Drum
When the PC Drum has been replaced, clear the "PC
Drum" count of "Port/Option 3/3" available from
"Counter" under the Tech. Rep. mode and make the
adjustment of exposure level in the Auto Exposure
mode.
NOTE
D-42