Specifications
8. Turn ON the Power Switch to bring the Lens to the full
size position.
9. Install the 4th/5th Mirrors Positioning Jig and, when
the hole in the cam is aligned with the pin on the jig,
tighten the set screw.
Be careful, the Scanner moves when the Power
Switch is turned ON.
NOTE
From a safety viewpoint, turn OFF the Power Switch
before tightening the set screw that secures the cam.
NOTE
1. Remove the AFR-9, Rear Upper Cover, Upper Rear
Cover, Control Panel Unit, Right Upper Cover, Left
Upper Cover, Upper Left Cover, and Original Glass.
2. Remove the Scanner.
3. Remove the Scanner positioning screws, one each at
the front and rear, and the Scanner fixing bracket.
4. Unplug one connector and remove four screws and
the Scanner Motor.
5. Remove the timing belt.
6. Using a flat-blade screwdriver, loosen the spring
anchors to unhook the beads of the front and rear
Scanner Drive Cables.
(12) Removal of the Scanner Drive Cables
D-37