Specifications
After 85 sec. or
40 sec. or 5 sec.
*
Timing depends on the surface temperature of the
Upper Fusing Roller and the difference in surface
temperature between the Upper and Lower Fusing
Rollers when S1 is turned ON.
(For details, see p. M-175.)
Approx. 250 msec.
OFF
Fusing Unit Ventilation Fan Motor M8
Approx. 450 msec.
ON
Approx. 400 msec.
ON
Suction Fan Motor M18 turns at full speed.
M6
Approx. 350 msec.
ON
PC Drum Drive Motor M5
Approx.
5 sec.
Developing Bias
C
The Start Key is pressed.
(A4 crosswise paper fed from 1st Drawer, full size, single copy cycle)
M6
Image Transfer/Paper
Separator Coronas
ON
Exposure Lamp / Image
Erase Lamp LA1/LA3
Approx. 60 msec.
CL1, M1
Paper Leading Edge Sensor PC27 is blocked ( L ).
Approx. 50 msec.
M2, M3
ON
OFF
ON
Optical Section Cooling Fan Motor / Ventilation Fan
Motor / Toner Suction Fan Motor / Power Supply
Unit Cooling Fan Motor M17/M19/M20/M29
Vertical Transport Sensor 1 PC10 is blocked ( L ).
OFF
= The following sequence is when making a single copy in full size on A4
crosswise fed from the 1st Drawer. =
ON
ON
Main Erase Lamp LA2
PC Drum Charge Corona
Pre-Image Transfer Erase
Lamp / Pre-Cleaning Erase
Lamp LA4/LA5
ON
ON
Paper Take-Up Motor / Vertical Transport Motor / Transport
Motor M1/M2/M3
1st Drawer Paper Take-Up Clutch CL1
ON
➀
M-8