Specifications
24-3. Gate Switching Mechanism/Control
•
When paper is to be stored into the Duplex Unit, the Gate Switching Lever
is operated as necessary according to the paper size to select Gate 1 or
Gate 2.
•
The Gate Switching Lever is operated by Duplex Unit Gate Switching
Solenoid SL2 which is energized or deenergized according to the paper
size to select Gate 1 or Gate 2 as shown in Table 1 on the next page.
•
SL2 is operated at the same time when the paper take-up sequence starts.
•
When the paper to be stored is 298 mm long or more, SL2 is energized to
swing open the Gate Switching Lever to allow the paper through Gate 2.
•
When the paper to be stored is 297 mm long or less, SL2 is deenergized,
allowing the paper through Gate 1.
Duplex Unit Gate Switching Solenoid SL2
Gate 1
298 mm long or more
297 mm long or less
Gate 2
Gate Switching Lever
SL2 ON
298 mm long or more
SL2 OFF
297 mm long or less
M-189