Specifications

24-3. Gate Switching Mechanism/Control
When paper is to be stored into the Duplex Unit, the Gate Switching Lever
is operated as necessary according to the paper size to select Gate 1 or
Gate 2.
The Gate Switching Lever is operated by Duplex Unit Gate Switching
Solenoid SL2 which is energized or deenergized according to the paper
size to select Gate 1 or Gate 2 as shown in Table 1 on the next page.
SL2 is operated at the same time when the paper take-up sequence starts.
When the paper to be stored is 298 mm long or more, SL2 is energized to
swing open the Gate Switching Lever to allow the paper through Gate 2.
When the paper to be stored is 297 mm long or less, SL2 is deenergized,
allowing the paper through Gate 1.
Duplex Unit Gate Switching Solenoid SL2
Gate 1
298 mm long or more
297 mm long or less
Gate 2
Gate Switching Lever
SL2 ON
298 mm long or more
SL2 OFF
297 mm long or less