Specifications

<Control>
SL11 is energized 300 msec. after Turnover Feed Sensor PC37 has
gone from LOW to HIGH as the trailing edge of the paper moves past it.
The solenoid remains energized for 100 msec.
1075T124CB
H
L
ON
OFF
Turnover Feed
Sensor (PC37)
100 msec.
220 msec.
Duplex Unit Turnover
Switching Solenoid (SL11)
Leading Edge of Paper Trailing Edge of Paper
Paper Present
SL11 is energized and deenergized by the signal output from pin 2 of
PJ6A on Duplex Unit S/P Board PWB-G.
1075C30MAA
M-185