Specifications

Cleaning Web Drive Motor M16 Control
Cleaning Web Drive Motor M16 is energized by a LOW M16 Remote signal
output from pin 2 of PJ4A on Master Board PWB-A, which occurs each
time when five copies have been made.
The LOW M16 Remote signal output from pin 2 of PJ4A is input to pin 5 of
PJ10 on M14/M16 Drive Board PWB-O. Then, power (ac converted from
dc) is supplied from pins 3 and 4 of PJ20 on PWB-O to M16, turning M16
about one turn.
1075C28MAA
M-171