Specifications
◆ Fusing Motor M6 Control
•
M6 is energized at the same time when the Start Key is pressed and
deenergized approx. 600 msec. after the trailing edge of the last copy has
deactivated Paper Exit Sensor PC36. (The Start Key should be pressed
when the copier is ready to make copies after having completed warming
up.)
•
M6 is energized when a LOW M6 Remote signal is output from pin 13 of
PJ7A on Master Board PWB-A.
ON
OFF
Fusing Motor
(M6)
Paper Exit Sensor
(PC36)
1075T102CA
H
L
Start Key ON
Energized
No Copy
Last Copy
The trailing edge of
the last copy moves
past PC36.
600 msec
1075C27MAA
M-168