Specifications

18-6. Cleaning Bias (Option)
A Cleaning Bias Seal can be installed optionally.
It is installed according to the type of copy paper the user uses.
It must be installed if the user uses acid paper which contains a lot of talc.
A bias voltage of approx. DC+410V is applied to the Cleaning Bias Seal by
Seal Bias HV3, thereby attracting talc from the surface of the PC Drum.
The cleaning bias is turned ON and OFF by the signal output from pin 95 of
IC4A on Master Board PWB-A.
<Cleaning Bias ON Timing>
Approx. 120 msec. after Scanner Control Processor Board PWB-J has
output a TRON (registration) signal, HV3 is turned ON to output the bias
voltage.
<Cleaning Bias OFF Timing>
HV3 is turned OFF approx. 890 msec. after PWB-J has output a SCEND
signal.
1075C18MAA
Cleaning Bias Seal
M-159