Specifications

16-6. Synchronizing Roller Drive Control
The Synchronizing Rollers are driven by Synchronizing Motor M4.
M4, a stepping motor, is controlled by energizing the four internal coils
using pulse signals output from pins 2, 3, 6, and 7 of IC2T on
Synchronizing Motor Control Board PWB-T, as controlled by Master Board
PWB-A.
The Synchronizing Rollers are started in synchronism with the Registration
signal (TRON).
*
The BASE signal is output when the Scanner reaches a given point in its
scan motion.
*
The TRON signal is output from Scanner Control Processor Board PWB-J
at a given time after the Image Leading Edge signal (BASE) has been
output.
The Synchronizing Rollers are stopped at a given time after the trailing
edge of the paper has moved past Paper Leading Edge Sensor PC27.
The Synchronizing Rollers are driven at the following timing.
1075T122CA
90
msec.
Paper Leading Edge
Sensor (PC27)
Transport Roller Sensor
(PC26)
TRON
H
L
H
L
H
L
Fusing Motor (M6)
ON
OFF
ON
OFF
Synchronizing Motor
(M4)
90
msec.
90
msec.
M-140