Specifications
13-13. Toner Suction Fan Motor
•
This copier is provided with a Suction Duct under the 2nd Sleeve/Magnet
Roller. Toner particles from the Developing Unit are drawn in through the
Suction Duct so that they will not fall over the Pre-Image Transfer Guide
Plate and Image Transfer/Paper Separator Coronas Unit.
•
The toner particles are drawn through the Suction Duct and collected by
the Air Filter as the air is drawn out of the copier by Toner Suction Fan
Motor M20.
•
M20 is energized and deenergized by the signal output from pin 49 of IC5A
on Master Board PWB-A.
<M20 Energization Timing>
M20 is energized at the same time when PC Drum Drive Motor M5 is
energized (p. M-26).
<M20 Deenergization Timing>
M20 is deenergized approx. 4,600 msec. after the trailing edge of the last
copy has moved past Paper Exit Sensor PC36.
Toner Suction Path
Suction Duct
Air Filter
1075M070AA
M20
Air
1075M071AA
2nd Air Filter
1st Air Filter
1075C12MAA
M-92