Specifications

<Main Hopper Toner Replenishing Motor M14 Control>
Main Hopper Toner Replenishing Motor M14 is energized and
deenergized by the output from pin 69 of IC4A on Master Board PWB-A.
M14 is energized when a toner-empty condition is detected in the Sub
Hopper (see p. M-83). It is deenergized when Toner Bottle Home
Position Sensor PC30 is blocked, at which time the Toner Supply Port of
the Toner Bottle is located on the top.
1075C09MAA