Specifications
13-8. Sub Hopper Toner Empty Detecting Mechanism/Control
<Toner Empty Detecting Mechanism>
•
A toner-empty condition in the Sub Hopper is detected by the magnet
that turns at the same time as the Sub Hopper Toner Agitating Lever to
actuate and deactuate Sub Hopper Toner Empty Switch S8.
•
While the amount of toner in the Sub Hopper is more than the
predetermined one, the magnet is pushed upwards by the toner as it first
meets the toner during its downward swing. It thereafter turns with a
smaller turning radius, leaving a greater distance from S8. S8 therefore
remains deactuated.
•
When the amount of toner in the Sub Hopper is less than the
predetermined one, the magnet turns with a greater turning radius and
actuates S8 as it nears S8 during its downward swing. This results in S8
being repeatedly actuated and deactuated. When the cumulative period
of time during which S8 remains actuated exceeds a predetermined
value, the copier CPU determines that the Sub Hopper has run out of
toner.
= Toner Full =
Sub Hopper Toner Agitating Lever
Magnet
S8 : OFF
= Toner Empty =
S8 : ON
M-82