Service manual

FrameMaker Ver.5.5(PC) EP1054/EP1085/EP2030 SWITCHES ON PWBs/TECH. REP. SETTINGS
98.06.09
S-14
[User Mode]
Function No.
Setting (The default is .)
U-18
✽
For 23 cpm
Copier only
<Priority Orig. Copy Type>
Determine the orig. copy type automatically selected when the
Power Switch is turned ON or Panel Reset key is pressed. The setting
made in “C-40 (Orig. Copy Type)” available as one of the Tech.
Rep. Choice functions determines the details of orig. copy type
selected by the setting of this function.
NOTE
2in1 = Enabled when an ADF is mounted.
2 = Enabled when a Duplex Unit is mounted.
U-20 <Auto Clear ON/OFF>
Select whether or not to activate the auto clear (panel reset) function
after the lapse of a given period of time after a copy cycle has been
completed or a key on the control panel has been operated.
U-21 <Energy Saver ON Timing>
Select whether or not to set the copier into the Energy Saver mode
after the lapse of a given period of time after a copy cycle has been
completed or a key on the control panel has been operated.
NOTE
Except for 99, the setting data equals the time in minutes.
Highlighted
[When “0” is set for C-40] [When “1” is set for C-40]
Data Description Data Description
1
2
3
4
1
➡
1
1
➡
2
2
➡
2
1
➡
1 2in1
1
➡
2 2in1
1
2
3
4
1
➡
2
1
➡
2
2
➡
2
1
➡
2 2in1
1
➡
2 2in1
0 0
Data 0 1
Description Disabled Enabled: 30 sec. Enabled: 1 min.
2
Data Description Data Description
1
2
.
.
.
Enabled: 1 min.
Enabled: 2 min.
.
.
.
Enabled: 15 min.
.
.
.
97
98
99
.
.
.
Enabled: 97 min.
Enabled: 98 min.
Enabled: 240 min.
15