Service manual

FrameMaker Ver.5.5(PC) EP1054/EP1085/EP2030 SWITCHES ON PWBs/TECH. REP. SETTINGS
98.06.09
S-9
<Clearing Procedures>
•
Initialize Points PJ2
1. Turn OFF the Power Switch.
2. With PJ2 closed, turn ON the Power Switch.
3. In approx. 5 sec., open PJ2.
•
Memory Clear Test Point TP2
1. Turn OFF the Power Switch.
2. With the circuit across TP1 and 2 closed, turn ON the Power Switch.
3. In approx. 5 sec., open the circuit across TP1 and 2.
NOTE
•
If an erratic operation or display occurs, perform the clearing procedures in the order of
PJ2 and TP2.
•
When memory clear has been performed, make the necessary settings again.
<List of Data Cleared by Switches and Points>
❍
: Cleared
−
: Not cleared
Front Door
Open/Close
Trouble Reset
Switch
(S1)
Initialize
Points
(PJ2)
Memory Clear
Test Point
(TP2)
Misfeed display
❍❍❍❍
Malfunction display
(excluding Exposure
Lamp and fusing
malfunctions)
❍❍❍❍
Malfunction display
(including Exposure
Lamp and fusing
malfunctions)
− ❍❍❍
Erratic operation/display
−−❍❍
User mode
−−−❍
Service mode
−−−❍
F3/5/8 adjustment values
−−−❍
Adjust mode
−−−❍
Clearing Means
Data Cleared