Service manual

FrameMaker Ver.5.5(PC) EP1054/EP1085/EP2030 SWITCHES ON PWBs/TECH. REP. SETTINGS
98.06.09
S-9
<Clearing Procedures>
Initialize Points PJ2
1. Turn OFF the Power Switch.
2. With PJ2 closed, turn ON the Power Switch.
3. In approx. 5 sec., open PJ2.
Memory Clear Test Point TP2
1. Turn OFF the Power Switch.
2. With the circuit across TP1 and 2 closed, turn ON the Power Switch.
3. In approx. 5 sec., open the circuit across TP1 and 2.
NOTE
If an erratic operation or display occurs, perform the clearing procedures in the order of
PJ2 and TP2.
When memory clear has been performed, make the necessary settings again.
<List of Data Cleared by Switches and Points>
: Cleared
: Not cleared
Front Door
Open/Close
Trouble Reset
Switch
(S1)
Initialize
Points
(PJ2)
Memory Clear
Test Point
(TP2)
Misfeed display
❍❍❍❍
Malfunction display
(excluding Exposure
Lamp and fusing
malfunctions)
❍❍❍❍
Malfunction display
(including Exposure
Lamp and fusing
malfunctions)
❍❍❍
Erratic operation/display
−−❍❍
User mode
−−−
Service mode
−−−
F3/5/8 adjustment values
−−−
Adjust mode
−−−
Clearing Means
Data Cleared