Service manual

FrameMaker Ver.5.5(PC) EP1054/EP1085/EP2030 DIS/REASSEMBLY, ADJUSTMENT
98.04.13
D-34
Cleaning of the Upper Pre-Image Transfer Guide Plate
Cleaning of the Magnet Roller Lower Filter
NOTE
At reinstallation, press the Toner Antispill Mylar up
against the Imaging Unit Housing and the rear side of
the copier (in the directions of the arrows) and press
the Bias Seal up against the Imaging Unit Housing and
the front side of the copier (in the directions of the
arrows).
1139D158AA
17. Remove two screws and the Upper Pre-Image
Transfer Guide Plate.
1139D159AA
18. Using a brush, whisk toner and dust off the surface
of the Upper Pre-Image Transfer Guide Plate.
1139D160AA
19. Using a brush, whisk toner and dust off the Magnet
Roller Lower Filter.
(No Magnet Roller Lower Filters are mounted in the
copiers for the U.S.A., Canada, and Europe.)
1139D161AA
20. Refit the parts to the Imaging Unit and reinstall the
Imaging Unit in the copier.
21. Charge fresh starter and make the ATDC adjust-
ment. See p. D-57.
1139D020AA