Service manual

FrameMaker Ver.5.5(PC) EP1054/EP1085/EP2030 DIS/REASSEMBLY, ADJUSTMENT
98.04.13
D-33
Cleaning of the PC Drum Paper Separator Fingers
Cleaning of the Ds Positioning Collars
Cleaning of the Paper Dust Remover
Replacement of the Toner Antispill Mylar
10. Using a soft cloth dampened with alcohol, wipe
clean the Paper Separator Fingers.
NOTE
Clean the Paper Separator Fingers carefully as its tip
is easy to bend.
1174D002AA
11. Using a soft cloth dampened with alcohol, wipe
clean the Ds Positioning Collars.
1139D163AA
12. Remove two screws, two compression coil springs
and the Synchronizing Roller Unit.
NOTE
When removing the Synchronizing Roller Unit, use
care not to lose the compression coil springs.
At reinstallation, fit the close-coiled end of the springs
to the bosses on the Imaging Unit.
1139D155AA
13. Remove the Synchronizing Roller.
14. Using a brush, whisk the dust and dirt off the Filter.
1139D156AA
15. Remove two screws and the Bias Seal.
(No Bias Seals are mounted in the copiers for the
U.S.A., Canada, and Europe.)
16. Remove two screws and the Toner Antispill Mylar
and replace the Mylar.
1139D157AA