FrameMaker Ver.5.5(PC) EP1054/EP1085/EP2030 TROUBLESHOOTING
98.05.15
T- 2 5
Transport/Separator Misfeed Clearing Procedure
Symptom
Step
Check Item
Result
Action
Paper is station-
ary before the
Synchronizing
Roller.
1
Is the paper curled, waved,
or damp? YES
Change the paper.
Instruct the user in how to
store the paper.
2
Check Paper Leading Edge
Detecting Sensor PC54
See p. T-2 (PWB-A (IC4A)
APC6).
YES Replace PWB-A.
NO
Check the Actuator for
operation.
Check PC54.
3
Check Synchronizing Roller
Clutch CL1.
Does the voltage across
PJ5A-4A on PWB-A and
GND change from DC24V
to DC0V after the Start
Key has been pressed?
YES Check the Clutch.
NO
Replace PWB-A.
4
Is a given length of loop
formed before the Synchro-
nizing Roller?
NO
Adjust the loop length or
clean or replace the Trans-
port Rollers.
Paper is station-
ary near the PC
Drum.
5
Is the Pre-Image Transfer
Guide Plate deformed or dirty?
YES
Correct or clean the Guide
Plate.
6
Is the Corona Unit Cleaning
Lever (Lower) in correct
position?
NO
Place the Lever in position.
7
Are the Image Transfer/
Paper Separator Corona
Wires deteriorated or dirty?
YES
Clean or replace the Wires.
8
Are the Paper Guides
deformed or dirty?
YES
Clean or replace the Paper
Guides.
9
Are the Synchronizing Roll-
ers deformed, worn, or dirty
with paper dust?
YES
Clean or replace the Syn-
chronizing Rollers.
Paper is wedged
at the Paper Sep-
arator Fingers.
10
Are the Paper Separator
Fingers deformed or dirty? YES
Correct or clean, or replace,
the Paper Separator Fingers.
Paper is station-
ary before the
Suction Belts.
11
Check Transport Roller
Sensor PC51. See p. T-2
(PWB-A (IC4A) APC7).
NO
Check the Actuator for
operation.
Check PC51.
12
Check Paper Leading Edge
Detecting Sensor PC54.
See p. T-2
(PWB-A (IC4A) APC6).
YES Replace PWB-A.
NO
Check the Actuator for
operation.
Check PC54.
13
Do the Suction Belts turn
properly?
NO
Check the Belts and Drive
Gear.
14
Check Suction Fan Motor M4.
Does the voltage across
PJ5A-9A on PWB-A and
GND change from
DC24V to DC0V when
the Start Key is pressed?
YES
Check the DC24V line.
Check M4.
NO
Replace PWB-A.