[Service Mode Test]
– Components Energized in the Tests –
F1 : Deenergized in the load OFF mode.
F3/5 : The Scanner stops at the TRON position.
F6 : Turned ON and OFF alternately to make a checkered pattern.
Test No. Description
F6 <Image Erase Lamp Check>
This test checks whether the Image Erase Lamp turns ON and OFF
properly.
(It runs for one complete copy cycle.)
<Procedure>
Press the Start key after the copier has completed warming up.
This causes the lamp to make a checkered pattern.
F7
For 23 cpm
Copier only
<Original Size Detecting Unit Adjustment>
This test automatically adjusts the Original Size Detecting Sensors,
starting when the Start key is pressed. (It runs for 5 sec.)
F8 <ATDC Sensor Automatic Adjustment>
This test automatically adjusts the ATDC Sensor. (It runs for about 5
min.)
NOTE
For details, see DIS/REASSEMBLY, ADJUSTMENT.
F9 <IU Check, Optimum Exposure Adjustment>
Do not use this test as it is only for factory adjustment.
FA <Scanner/Image Erase Lamp Operation Check>
Do not use this test as it is only for factory adjustment.
F1 F2 F3 F4 F5 F6 F7 F8 F9 FA
Main Drive Motor
❍❍❍❍❍❍
❍❍
PC Drum Drive Motor
❍❍❍❍❍❍
❍❍
Fan Motors
❍❍❍❍❍❍
❍❍
Toner Replenishing Motor
−−−−−−
−−
HV (PC Drum Charge, Image
Transfer, grid)
−−−
❍❍
Bias (Developing, Separator, seal)
❍❍❍❍
❍❍
Scanner
−−
❍❍
Paper Take-Up Roll
−−−−
−−−−
Paper Transport Rollers
−−−−
−−−−
Synchronizing Rollers
−−−−
−−−−
Exposure Lamp
❍❍
−−
Main Erase Lamp
❍❍❍❍❍❍
❍❍
Image Erase Lamp
❍❍❍
PC Drum Paper Separator Fingers
−−−−
−−−−
Misfeed detection
−−−−
−−−−
Malfunction detection
❍❍❍❍❍❍❍❍❍❍
: Energized
: Remain deenergized
Test Ope rati on
Component