Service manual

Table Of Contents
(2186) 59
REPAIR GUIDE
Fig.1Fig.1
Fig.1Fig.1
Fig.1
Chromaticity
x=0.445∼0.455
0.405∼0.415
120∼180cd/㎡ (Ev10±0.3Ev)
Light Source-A Maintenance
OutLine
Because high accuracy of required light source-A is required when adjusting and confirming.
Measuring instrument
Chroma meter (CL-200)
Liminance meter (LS-100)
Light source-A (tungsten light)
Procedure
*Managements of the chromaticity and the luminance
1. Light the light source-A on.
2. Measure the chromaticity coodinate (x,y) with the chroma meter. (Fig. 1)
3. The result should be within the range of the following table.
* If the result is out of the range, adjust the light voltage of the light source-A through the slidax.
4. Measure the luminance with the luminance meter.
5. The result should be within the range of the following table.
*If the result is out of the range, adjust the distance of the light source-A.