Service manual

Table Of Contents
54 (2186)
REPAIR GUIDE
Fig. 1Fig. 1
Fig. 1Fig. 1
Fig. 1
Fig. 1Fig. 1
Fig. 1Fig. 1
Fig. 1
Sensitivity adjustment (CCD GAIN)
Required equipment
Luminance box
L-2101/L-2111 or multi camera tester: EF-8301
AE Master Lens
PC with preinstalled the 2186 adjustment program
USB-2 (USB cable)
AC Adapter AC-11
Procedure of the adjustment
1. Set camera to adjustment mode.
Refer to Starting up the 2186 adjustment program (in the adjustment mode) in P. 37.
2. Set the camera and the measuring instrument as shown on the Fig. 1.
3. Set the brightness of the Luminance box to EV 7.
4. Click CCD GAIN of the adjustment menu. Does it adjust? appears.
5. Click YES then automatic adjustment starts.
6. The adjustment is completed when OK is displayed on the adjustment menu.
Adjustment of the defective pixel (DEFECT PIXEL)
Required equipment
Luminance box
L-2101/L-2111 or multi camera tester: EF-8301
AE Master Lens
PC with preinstalled the 2186 adjustment program
USB-2 (USB cable)
AC Adapter AC-11
Procedure of the adjustment
1. Set camera to adjustment mode.
Refer to Starting up the 2186 adjustment program (in the adjustment mode) in P.37.
2. Set the camera and the measuring instrument as shown on the Fig.1.
3. Set the brightness of the Luminance box to EV 8.
4. Click DEFECT PIXEL of the adjustment menu.
Does it adjust? appears.
5. Click YES then automatic adjustment starts.
6. The adjustment is completed when OK is displayed on the
adjustment menu.