Service manual
Table Of Contents
- 1.pdf
- 3-4.pdf
- 5.pdf
- REPAIR GUIDE
- Precautions
- 1. Disassembly of the exterior parts
- ■Wires arrangement
- 2. Disassembly of the I/O FPC ASSY, MAIN PCB ASSY
- 3. Disassembly of the SUB PLATE L, BATTERY CHAMBER
- 4. Disassembly of the CCD ASSY, SHUTTER ASSY
- ■CCD inclination adjustment / repair
- 5. Disassembly-1 of the MIRROR BOX ASSY
- 6. Disassembly-2 of the MIRROR BOX ASSY
- 7. Disassembly-3 of the MIRROR BOX ASSY
- 8. Disassembly of the BATTERY CHAMBER, LCD 101
- 9. Disassembly of the TOP COVER ASSY
- 10. Disassembly of the FRONT COVER ASSY, BACK COVER ASSY
- ■Required adjustment, setting and confirmation items after repairing(exchanging parts)
- ■Related adjustment and required setting items
- ■Viewfinder Back Adjustment
- ■Preparing the 2186 adjustment program
- ■Starting up the 2186 adjustment program (in the adjustment mode)
- ■Adjustment of the PI-PR
- ■Adjustment of the frequency for camera shaking (FREQUENCY)
- ■Adjustment of the servo for camera shaking (SERVO)
- ■Adjustment of the gyro for camera shaking (GYRO)
- ■Adjustment of CCD Vsub voltage (VSUB)
- ■Setting for the adjustment of CCD AORI & CENTER
- ■Adjustment / Checking of CCD AORI & CENTER
- ■Manual Set SS & X-Sync. Time-lag Check
- ■Adjustment Manual Set SS
- ■Preparation before AF adjustment
- ■AF Area Adjustment
- ■Pitch Yaw Adjustment
- ■FLATNESS Adjustment
- ■EZ Check / Adjustment
- ■EZ Adjustment
- ■EZ Check
- ■EZ SHIFT
- ■Aperture Preset Check / Adjustment
- ■Check / Adjustment of the AE (AE)
- ■Sensitivity adjustment (CCD GAIN)
- ■Adjustment of the defective pixel (DEFECT PIXEL)
- ■Adjustment of white balance (WB)
- ■Adjustment of the camera shaking compensation (SHAKE GAIN)
- ■FLASH LEVEL SHIFT
- ■Setting of Destination (DESTINATION)
- ■CAMERA LOG
- ■LCD All Segment On
- ■Light Source-A Maintenance
- ■Error code on adjustment program
- ■Measuring instrument
- ■Subsidiary Materials
- REPAIR GUIDE
- 6.pdf
- TROUBLESHOOTING CHART
- 7.pdf
- 8.pdf
- 9.pdf
54 (2186)
REPAIR GUIDE
■■
■■
■
Fig. 1Fig. 1
Fig. 1Fig. 1
Fig. 1
■■
■■
■
Fig. 1Fig. 1
Fig. 1Fig. 1
Fig. 1
Sensitivity adjustment (CCD GAIN)
Required equipment
Luminance box
L-2101/L-2111 or multi camera tester: EF-8301
AE Master Lens
PC with preinstalled the 2186 adjustment program
USB-2 (USB cable)
AC Adapter AC-11
Procedure of the adjustment
1. Set camera to adjustment mode.
Refer to “Starting up the 2186 adjustment program (in the adjustment mode)” in P. 37.
2. Set the camera and the measuring instrument as shown on the Fig. 1.
3. Set the brightness of the Luminance box to EV 7.
4. Click “CCD GAIN” of the adjustment menu. “Does it adjust?” appears.
5. Click “YES” then automatic adjustment starts.
6. The adjustment is completed when “OK” is displayed on the adjustment menu.
Adjustment of the defective pixel (DEFECT PIXEL)
Required equipment
Luminance box
L-2101/L-2111 or multi camera tester: EF-8301
AE Master Lens
PC with preinstalled the 2186 adjustment program
USB-2 (USB cable)
AC Adapter AC-11
Procedure of the adjustment
1. Set camera to adjustment mode.
Refer to “Starting up the 2186 adjustment program (in the adjustment mode)” in P.37.
2. Set the camera and the measuring instrument as shown on the Fig.1.
3. Set the brightness of the Luminance box to EV 8.
4. Click “DEFECT PIXEL” of the adjustment menu.
“Does it adjust?” appears.
5. Click “YES” then automatic adjustment starts.
6. The adjustment is completed when “OK” is displayed on the
adjustment menu.