Service manual

Table Of Contents
52 (2186)
REPAIR GUIDE
Fig.1Fig.1
Fig.1Fig.1
Fig.1
Fig.2Fig.2
Fig.2Fig.2
Fig.2
Aperture Preset Check / Adjustment
Equipment Required
PC with preinstalled the 2186 adjustment program
HIT I/O Tester
Preset Signal Adapter
USB-2 (USB cable)
AC Adapter AC-11
Check
1. Set up the equipment as in Fig. 1, and set camera to M mode and Bulb.
2. Press Reset Button on HIT I/O Tester so that 00 appears in the display.
3. Set aperture to f/11, and release the shutter.
Check the reading in HIT I/O Tester is within the standard. (Reading appears while Shutter-release
Button is pressed all-the-way down.)
If the reading is out of standard, make Aperture Preset adjustment.
Adjustment
1. Set up the camera and measuring instruments as shown in Fig. 1.
2. Set the camera to the adjsutment mode.
Refer to Starting up the 2186 adjustment program (in the adjustment mode) in P. 37.
Attach the Preset Sinal Adapter to the camera, and then set to the adjustment mode.
Confirm that the aperture value is not indicated as -- on the LCD of the camera.
3. Press the Reset button of the H.I.T. I/O tester to reset the display to 00.
4. Select PRETRIGGER in the adjustment menu.
5. When Execute 1st release? appears, click OK.
6. Shutter-releasing is automaticallly done. Check the value of the H.I.T. I/O tester.
7. Press the Reset button of the H.I.T. I/O tester to reset the indicated value to 00.
8. When Execute 2nd release? appears, click OK.
9. The second shutter-releasing is automaticallly done. Check the value of the H.I.T. I/O tester.
10. Input the average value of 1st and 2nd shutter-releasing (Fig. 2), and then click OK.
11. Repeat step 5 to 10 for f/5, f/10, f/20 respectively.
12. OK appears on the adjustment menu when completed.
CameraCamera
CameraCamera
Camera
Exposure mode: M Exposure mode: M
Exposure mode: M Exposure mode: M
Exposure mode: M
Focus mode: MF Focus mode: MF
Focus mode: MF Focus mode: MF
Focus mode: MF
Standard f/11: Ab - bb
HIT I/O TesterHIT I/O Tester
HIT I/O TesterHIT I/O Tester
HIT I/O Tester
PRE/FLA: PRESET PRE/FLA: PRESET
PRE/FLA: PRESET PRE/FLA: PRESET
PRE/FLA: PRESET
Preset Signal AdapterPreset Signal Adapter
Preset Signal AdapterPreset Signal Adapter
Preset Signal Adapter
NOTE:These indications look similar
in HIT I/O Tester display
-------- 6
-------- b