Preparation before AF adjustment
Note: After replacing CCD MODULE ASSY and/or MIRROR BOX ASSY or its relative parts, always
perform AF Area Adjustment (pg. 46) to EZ Adjustment (pg. 49).
If customer says focus fucntion is not normal, perform this adjustment too.
Preparations
The following items should have been completed before starting AF adjustment.
1. Peform this adjustment without FRONT COVER ASSY, after disassemble.
2. When CCD sensor module is out of position after replacing CCD MODULE ASSY, tighten three AF
adjusting screws until they stop, then evenly loosen them by 0.4mm (1.14 turns).
Equipment Required
See the list on P.62 for the measuring instruments, tools and jigs.
PC with preinstalled the 2186 adjustment program
AF Master Lens
AE Master Lens
AF Chart I for 2163
AF Chart II for 2163
AF Chart III for 2163
USB-2 (USB cable)
AC Adapter AC-11
AF-Y/P Adjuster
AF Tripod Attachment-II
Grip Ring
Hexagon Bar Wrench (1.5) or Hexagon Screwdriver
Fluorescent (FL40S W-SDL) (EZ check and adjustment)
Flood Lamp (AF Area and Pitch Yaw adjustment)
(color temperature of 2800 degrees K and brightness
higher than or equal to EV 10)
AF Master LensAF Master Lens
AF Master LensAF Master Lens
AF Master Lens
Yaw Adjusting PlateYaw Adjusting Plate
Yaw Adjusting PlateYaw Adjusting Plate
Yaw Adjusting Plate
Pitch Adjusting PlatePitch Adjusting Plate
Pitch Adjusting PlatePitch Adjusting Plate
Pitch Adjusting Plate
AF-Y/P JigAF-Y/P Jig
AF-Y/P JigAF-Y/P Jig
AF-Y/P Jig
AF TripodAF Tripod
AF TripodAF Tripod
AF Tripod
Attachment-IIAttachment-II
Attachment-IIAttachment-II
Attachment-II
TripodTripod
TripodTripod
Tripod
Grip RingGrip Ring
Grip RingGrip Ring
Grip Ring
Setting for EZ check and adj.Setting for EZ check and adj.
Setting for EZ check and adj.Setting for EZ check and adj.
Setting for EZ check and adj.