REPAIR GUIDE
Fig. 1Fig. 1
Fig. 1Fig. 1
Fig. 1
Fig. 3Fig. 3
Fig. 3Fig. 3
Fig. 3
Fig. 2Fig. 2
Fig. 2Fig. 2
Fig. 2
Fig. 4Fig. 4
Fig. 4Fig. 4
Fig. 4
Numbers mean the degrees of rotating adjusting screwNumbers mean the degrees of rotating adjusting screw
Numbers mean the degrees of rotating adjusting screwNumbers mean the degrees of rotating adjusting screw
Numbers mean the degrees of rotating adjusting screw
Arrows mean the direction of rotating adjusting screwArrows mean the direction of rotating adjusting screw
Arrows mean the direction of rotating adjusting screwArrows mean the direction of rotating adjusting screw
Arrows mean the direction of rotating adjusting screw
Procedure of CCD AORI checking
1. Set 2186 camera to adjustment mode.
Refer to Starting up the 2181 adjustment program (in the adjustment mode) in P. 37.
2. Click AORI & CENTER in adjustment menu.
3. Click 2186 when Please select master data appears. (Fig. 1)
4. Click MASTER BODY AORI & CENTER in AORI & CENTER Adjustment menu(Fig. 2) and
perform shutter-release.
5.Setting Data of master body has complete!appers when reading Master body data is completed.
6. Click END in AORI & CENTER Adjustment menu.
7. Click ADJUSTMENT END in adjustment menu.
8. Set target camera to adjustment mode. Exchange Master camera for target camera.
Be careful to exchange camera to avoid any change to the setting.
9. Click AORI & CENTER in adjustment menu. Select the model specified as master body in Fig.1.
10. Click CHECKAORI in AORI & CENTER Adjustment menu. (Fig. 2)
11. Check the value disPlayed in Aori Adjusment window, whether value ofC and dPI is within the
following standard. (Fig. 3)
Standard value of C: From -10 to 10
Standard value of dPI: From -10 to 10