Service manual
Table Of Contents
- 1.pdf
- 3-4.pdf
- 5.pdf
- REPAIR GUIDE
- Precautions
- 1. Disassembly of the exterior parts
- ■Wires arrangement
- 2. Disassembly of the I/O FPC ASSY, MAIN PCB ASSY
- 3. Disassembly of the SUB PLATE L, BATTERY CHAMBER
- 4. Disassembly of the CCD ASSY, SHUTTER ASSY
- ■CCD inclination adjustment / repair
- 5. Disassembly-1 of the MIRROR BOX ASSY
- 6. Disassembly-2 of the MIRROR BOX ASSY
- 7. Disassembly-3 of the MIRROR BOX ASSY
- 8. Disassembly of the BATTERY CHAMBER, LCD 101
- 9. Disassembly of the TOP COVER ASSY
- 10. Disassembly of the FRONT COVER ASSY, BACK COVER ASSY
- ■Required adjustment, setting and confirmation items after repairing(exchanging parts)
- ■Related adjustment and required setting items
- ■Viewfinder Back Adjustment
- ■Preparing the 2186 adjustment program
- ■Starting up the 2186 adjustment program (in the adjustment mode)
- ■Adjustment of the PI-PR
- ■Adjustment of the frequency for camera shaking (FREQUENCY)
- ■Adjustment of the servo for camera shaking (SERVO)
- ■Adjustment of the gyro for camera shaking (GYRO)
- ■Adjustment of CCD Vsub voltage (VSUB)
- ■Setting for the adjustment of CCD AORI & CENTER
- ■Adjustment / Checking of CCD AORI & CENTER
- ■Manual Set SS & X-Sync. Time-lag Check
- ■Adjustment Manual Set SS
- ■Preparation before AF adjustment
- ■AF Area Adjustment
- ■Pitch Yaw Adjustment
- ■FLATNESS Adjustment
- ■EZ Check / Adjustment
- ■EZ Adjustment
- ■EZ Check
- ■EZ SHIFT
- ■Aperture Preset Check / Adjustment
- ■Check / Adjustment of the AE (AE)
- ■Sensitivity adjustment (CCD GAIN)
- ■Adjustment of the defective pixel (DEFECT PIXEL)
- ■Adjustment of white balance (WB)
- ■Adjustment of the camera shaking compensation (SHAKE GAIN)
- ■FLASH LEVEL SHIFT
- ■Setting of Destination (DESTINATION)
- ■CAMERA LOG
- ■LCD All Segment On
- ■Light Source-A Maintenance
- ■Error code on adjustment program
- ■Measuring instrument
- ■Subsidiary Materials
- REPAIR GUIDE
- 6.pdf
- TROUBLESHOOTING CHART
- 7.pdf
- 8.pdf
- 9.pdf
(2186) 41
REPAIR GUIDE
Adjustment / Checking of CCD AORI & CENTER
Outline
Peform adjustment of CCD position and perspective.
*See Setting the camera and the chart when adjusting the CCD AORI&CENTER (P. 40).
With 2186 adjustment program, master body for CCD Aori & Center is selectable from 2181 and 2186.
Preparation of the adjustment
*When CCD sensor module is out of position after replacing CCD MODULE ASSY, tighten three AORI
adjusting screws until they stop, then evenly loosen them by 3 turns.
1. Perform this adjustment without BACKCOVER ASSY, after disassembling from step 1 to step 4 in P. 4.
2. Set Master body and chart.
Refer to “Setting of Master body and chart for the adjustment of CCD position” in P. 40
3. Set camera to adjustment mode.
Refer to “Starting up the 2186 adjustment program (in the adjustment mode)” in P. 37
Preparation of the adjustment when using 2181 as a master body instead of 2186
1. Set 2181 master body to adjustment mode, and start up the 2181 adjustment program.
2. Click “AORI & CENTER” of the adjustment menu, then click MASTER BODY "AORI & CENTER".
“Does it adjust?” appears.Select 2186 adjustment program.
3. “Setting Data of master body has complete!” appears when data readout completed.
4. Click “END” in “AORI & CENTER” adjustment menu.
Do not close the adjustment screen. Otherwise, the Master body data will be lost.
5. Select 2186 in the “CAMERA CODE” list and click “START” adjustment program.
6. Start from step 8 of the adjustment procedure.
Adjustment of CCD center position and AORI
1. Set 2186 master body to adjustment mode.
2. Click “AORI & CENTER” in adjustment menu.
3. Click “2186” when “Please select master data” appears. (P. 42 Fig. 1)
4. Click MASTER BODY “AORI & CENTER” in AORI & CENTER Adjustment menu. (Fig. 2)
5. “Setting Data of master body has complete!” is displayed, data readout completed.
6. Click CHECK “AORI” and check the data.
7. Click “END” in AORI & CENTER Adjustment menu.
8. Set target camera to adjustment mode.
9. Exchange Master camera for target camera.
Be careful to exchange cameras to avoid any change to the setting.
10. Click AORI & CENTER in Adjustment menu.
11. Click the model which was selected as master body in Fig.1 P.42.
12. Click ADJUSTMENT “CENTER”When “Does it adjust?” is displayed, click “YES”.
13. “OK” is displayed when “CENTER” adjustment completed.
14. Click ADJUSTMENT “AORI”
15. Check the numbers displayed in Aori Adjusment window, whther value of“C” and “dPI” is in the
range of standard value. (Fig. 3)
Standard value of C: Between -30 and 30
Standard value of dPI: Between -30 and 30
If displayed value is out of range, peform the following adjustment.
Turn AORI adjusting screws (2706) following the direction in Aori Adjustment window (Fig .4)
16. By clicking “RETRY”, repeat step 15 until displayed value is within the standard.
17. If the result is within the standard, click “OK” in AORI adjustment menu to complete.
Perform “Resolving Power” check according to the check list, P.4, after finishing adjustment.
Repeat adjustment of CCD center position and AORI until the result of this check satisfies the stan-
dard.