Service manual

Table Of Contents
(2186) 41
REPAIR GUIDE
Adjustment / Checking of CCD AORI & CENTER
Outline
Peform adjustment of CCD position and perspective.
*See Setting the camera and the chart when adjusting the CCD AORI&CENTER (P. 40).
With 2186 adjustment program, master body for CCD Aori & Center is selectable from 2181 and 2186.
Preparation of the adjustment
*When CCD sensor module is out of position after replacing CCD MODULE ASSY, tighten three AORI
adjusting screws until they stop, then evenly loosen them by 3 turns.
1. Perform this adjustment without BACKCOVER ASSY, after disassembling from step 1 to step 4 in P. 4.
2. Set Master body and chart.
Refer to Setting of Master body and chart for the adjustment of CCD position in P. 40
3. Set camera to adjustment mode.
Refer to Starting up the 2186 adjustment program (in the adjustment mode) in P. 37
Preparation of the adjustment when using 2181 as a master body instead of 2186
1. Set 2181 master body to adjustment mode, and start up the 2181 adjustment program.
2. Click AORI & CENTER of the adjustment menu, then click MASTER BODY "AORI & CENTER".
Does it adjust? appears.Select 2186 adjustment program.
3. Setting Data of master body has complete! appears when data readout completed.
4. Click END in AORI & CENTER adjustment menu.
Do not close the adjustment screen. Otherwise, the Master body data will be lost.
5. Select 2186 in the CAMERA CODE list and click START adjustment program.
6. Start from step 8 of the adjustment procedure.
Adjustment of CCD center position and AORI
1. Set 2186 master body to adjustment mode.
2. Click AORI & CENTER in adjustment menu.
3. Click 2186 when Please select master data appears. (P. 42 Fig. 1)
4. Click MASTER BODY AORI & CENTER in AORI & CENTER Adjustment menu. (Fig. 2)
5. Setting Data of master body has complete! is displayed, data readout completed.
6. Click CHECK AORI and check the data.
7. Click END in AORI & CENTER Adjustment menu.
8. Set target camera to adjustment mode.
9. Exchange Master camera for target camera.
Be careful to exchange cameras to avoid any change to the setting.
10. Click AORI & CENTER in Adjustment menu.
11. Click the model which was selected as master body in Fig.1 P.42.
12. Click ADJUSTMENT CENTERWhen Does it adjust? is displayed, click YES.
13. OK is displayed when CENTER adjustment completed.
14. Click ADJUSTMENT AORI
15. Check the numbers displayed in Aori Adjusment window, whther value ofC and dPI is in the
range of standard value. (Fig. 3)
Standard value of C: Between -30 and 30
Standard value of dPI: Between -30 and 30
If displayed value is out of range, peform the following adjustment.
Turn AORI adjusting screws (2706) following the direction in Aori Adjustment window (Fig .4)
16. By clicking RETRY, repeat step 15 until displayed value is within the standard.
17. If the result is within the standard, click OK in AORI adjustment menu to complete.
Perform Resolving Power check according to the check list, P.4, after finishing adjustment.
Repeat adjustment of CCD center position and AORI until the result of this check satisfies the stan-
dard.