Service manual

Table Of Contents
(2186) 37
REPAIR GUIDE
Fig.1Fig.1
Fig.1Fig.1
Fig.1
Fig.2Fig.2
Fig.2Fig.2
Fig.2
Starting up the 2186 adjustment program (in the adjustment mode).
Outline
Connect the camera and PC with USB-2 and start up the camera in the "adjustment mode."
"Adjustment mode" means the condition of that the camera can contact with the 2186 adjustment program
in the PC.
Starting up the 2186 adjustment program (in the adjustment mode).1
1. Set camera to M mode.
2. Turn the Main switch off, and then turn it on with pressing and holding the UP key of the controller,
Menu button, and shutter release button partway down (S1).
Frame counter will be BBBB and the camera starts up in adjustment mode. (Fig.1)
3. Connect camera and the PC with USB cable, after starting camera by adjustment mode.
4. Start up the 2181 adjustment program, "KMdsc_cs.exe."
Please select camera code. appears.
5. Select 2186 from CAMERA CODE in the window, according to the display.
Please connect a camera and click START. appears.
6. Click the START button.
Camera Boot mode READ-OUT has completed. appears. (Fig. 2)
Starting up the 2186 adjustment program (in the adjustment mode).2
In the condition that a function button cannot be used such as Aori adjustment, start up the camera using
a CF card with adjustment program.
1. Insert the CF card with Main switch on, no power supply (battery), M mode.
2. Connect camera and the PC with USB cable.
3. Insert battery (power supply) while pressing the lens lock button.
4. Release the lens lock button after access lamp lit, The camera starts from the CF card.
Frame counter will be BBBB and the camera starts up in adjutment mode. (Fig.1)
5. Same as 4, 5, 6 of the above method 1.
Quitting the 2186 adjusting program and cancel adjustment mode of camera
1. Click "ADJUSTMENT END" in the window of the 2186 adjustment program.
2. Remove the AC adapter or battery.
Adjustment items in the 2186 Adjustment Program
PI-PR
FREQUENCY
SERVO
GYRO
VSUB
AORI & CENTER
SS
AF (AREA , PITCH / YAW)
FLATNESS
EZ
PRETRIGGER
AE
CCD GAIN
DEFECT PIXEL
WB
SHAKE GAIN
FLASH LEVEL
DESTINATION