Service manual

Table Of Contents
16 (2186)
REPAIR GUIDE
Fig. 1Fig. 1
Fig. 1Fig. 1
Fig. 1
Fig. 2Fig. 2
Fig. 2Fig. 2
Fig. 2
CCD inclination adjustment / repair
Check
Setup the equipments so that the camera faces to a subject at accurate level;
1. Use a copy stand or place a mirror on the wall.
2. Use a 50/1.7 lens for inspection.
3. Measure an angle of gradient by Photoshop.
If it is beyond +/- 1.0 degree, be sure to implement the Repair method (mentioned later).
If it is between +/- 0.5 and +/- 1.0 degree, implement the Repair method (mentioned later) upon
request of the user.
If it is within +/- 0.5 degree, implement the Inspection again to correct measurement error.
Adjustment
1. Remove the CCD SLANTING STOPPER. (Fig. 1)
2. Check and adjust of a hexagon eccentric pin. (Fig. 2)
* 60-degree (0.42 degree of CCD inclination) rotation is possible respectively from a neutral position to
a clock and a counterclockwise direction.
The adjustment over 60 degrees is impossible. (CCD SLANTING STOPPER cannot be attached.)
Rotate 60 degrees clockwise, when the image slants to the right.
Rotate 60 degrees counterclockwise, when the image slants to the left.
Repair (when it cannot be adjusted by the above adjustment method)
1. Disassemble the body so that the CCD Assy can be removed.
2. Cut the two posts (fig. 3); one for positioning and the other for direction standard between the CCD
holder (in the Slider Assy) and the heat sink plate (in the CCD Assy).
3. Install an insulation sheet on the terminal of the CCD Assy or on the contact surface of the CCD holder.
(to prevent short-circuit between the CCD terminal and CCD holder)
4. Adjust the position of the CCD Assy and then assemble it.
When an image tilts to the right, turn it clockwise.
When an image tilts to the left, turn it counterclockwise.
The tilt can be corrected approx. +/- 0.7 degree at the max. by shifting double faced tape on the LPF*.
*Prepare a spare parts of Tebure Assy with the above mentioned step 2 applied separately and shift the
position by using it. Donot shift the tape on the users Tebure Assy to prevent the Tebure Assy from
being broken.
5. Assemble the whole unit.
6. Implement the Inspection.
If the variance is beyond +/- 0.5 degree, replace the Tebure Assy. Implement the Inspection again.
7. Perform adjustment of CCD AORI & CENTER, camera shaking compensation after the completion of
repair.
CCD SLANTING STOPPERCCD SLANTING STOPPER
CCD SLANTING STOPPERCCD SLANTING STOPPER
CCD SLANTING STOPPER
(Neutral position)(Neutral position)
(Neutral position)(Neutral position)
(Neutral position)
Fig. 3Fig. 3
Fig. 3Fig. 3
Fig. 3