Service manual

Table Of Contents
(2186) 9
KONICA MINOLTA PHOTO IMAGING, INC.
This information should be filed in your service manual.
SUPPLYMENTARY INFORMATION
R606R606
R606R606
R606
R607R607
R607R607
R607
symptom Cause Measure
Exposure mode dial and WB
dial failure. Shutter release
failure (stays S2 ON). Self
LED stays lighting.
I/O FPC cover was scratched by the main chassis
edge, and short-circuit with the internal pattern.
I/O FC assy (2186-0406)
exchange
Flash UP is not detected.
Black lead wire was crushed under the shoe plate
by the assembly-operation mistake.
R606 and R607 on the top cover FPC were burned
and damaged.
INF missing
Short-circuit with adjacent pattern due to poor
insertion to the connector of IF LCD holder assy
FPC (inclination)
Connect FPC of IF
LCD holder assy.
Top cover FPC assy
(2186-0407) exchange,
W152 exchange and
arrangement