symptom Cause Measure
Eject lever does not lock.
Metal plate and a lever link component interfere.
A parting part and a lever link component
interfere.
Eject connector (9383-
0561-50) exchange
CF card cannot be inserted
fully.
At the time of reappearance, it is in the state
where CF card was inserted, and when pushing
eject button and taking out a card, a finger is
touching so that it may support CF card.
It recurs in the timing.
Eject connector (9383-
0561-50) exchange
F -- Display BL contact FPC pattern dirt
BL contact holder assy
(2186-0150) exchange
Anti-Shake access lamp stays
on.
Carbon shaft holder SP at the slider A side of
Slider assy came off.
Reinstall Carbon shaft
holder SP of Slider assy
(2186-0901)
Abnormal image -- entirely
black
IC on CCD PCB destroyed (output 0V).
Presumption: It was the full destruction of IC
which was damaged by the connection mistake to
a unit checker.
CCD assy (2186-0271)
exchange
Abnormal image -- entirely
white
IC on CCD PCB destroyed (output 2V).
Presumption: It is the full destruction of IC
which was damaged by the connection mistake to
a unit checker.
CCD assy (2186-0271)
exchange
Preview button does not
function
No click feeling due to misalignment of SW FPC.
Preview button SW
FPC re-installation