Service manual
Table Of Contents
- Specifications
- Scanner Type
- Usable Film Type
- Scanning Dimension
- Optical Resolution
- Scanning method
- Image Sensor
- Scan Time (excluding the data transfer time to PC)
- AD Conversion
- Output
- Dynamic Range
- Light Source
- Focus
- Others
- Interface
- Power Requirements
- Power Consumption
- Size
- Weight
- Standard Accessory
- Operating Environment
- Storage Environment
- System Requirements
- Parts List
- Repair Guide
- Checklist
- 2890plu.pdf
- 2890rg_eu.pdf
- 2890cl_eu.pdf

12 (2890) A
CHECK LIST
Color Balance
Chart +/-
Step 1 White 10 or less
Step 2 Gray2 10 or less
Step 3 Gray3 10 or less
Step 4 Gray4 10 or less
Step 5 Gray5 10 or less
Step 6 Black 16 or less
Color Reproduction
Chart a* b*
B
23"10
-53 ± 10
G
-44"10
13 ± 10
R
48"10
46 ± 10
Y
-5"10
51 ± 10
M
50"10
-19 ± 10
C
-18"10
-32 ± 10
Equipment Required
PC/AT compatibles
CPU Pentium III or later
RAM 500MB or more
HDD Approx. 2GB or more of available hard-disk space
OS Windows 98, 98SE, Me, 2000 Professional
Monitor 1024 x 768 (pixels) is recommended. High Color (16-bit)
2890Adjustment Program FD Version 1.0 <2890-0001-75>
2887Adjustment Program CD Version 1.0 <2887-0001-75>
Scanner Gauge Chart (35mm) <7982-5002-01>
Color Chart Slide (35mm) <7982-5005-01>
Slide Mount Holder (SH-M10)
Microsoft Excel
DiMAGE Scan Ver. 1.1.0 (CD-ROM)
AC Adapter
DiMAGEScan.ini
90Color135.dll
2890_data sheet.xls