Service manual
Table Of Contents
- Specifications
- Scanner Type
- Usable Film Type
- Scanning Dimension
- Optical Resolution
- Scanning method
- Image Sensor
- Scan Time (excluding the data transfer time to PC)
- AD Conversion
- Output
- Dynamic Range
- Light Source
- Focus
- Others
- Interface
- Power Requirements
- Power Consumption
- Size
- Weight
- Standard Accessory
- Operating Environment
- Storage Environment
- System Requirements
- Parts List
- Repair Guide
- Checklist
- 2890plu.pdf
- 2890rg_eu.pdf
- 2890cl_eu.pdf

(2890) A 9
CHECK LIST
Scan
1) Click Start > Programs > Minolta DiMAGE Scan Ver. 1.1 > DiMAGE Scan Utility.
2) Set the preferences as below.
Scanning condition
Film format 35mm
Film Type Color Positive
Input resolution 540 dpi
3) Click on the Prescan button to prescan the chart.
Check that the chart is scanned as shown and that it is not underexposure.
4) Click on the Point AF button and move the mouse pointer to the center of the image
and then start the Auto Focus.
5) Make sure that all the area of the image is selected and click on the Scan button.
6) Save the image as .BMP file.
7) Add “_P0” after the file name as suffix (***(file name)_P0.BMP).
Measurement
1) Click Start > Program > DPEV > ColorEV.
2) Click Setup > Measure, and set the preference as below.
Measurement condition
Category Scanner
Resolution 540 dpi
Chart 135
Ver 6
Standard 90Color135.txt
Data Out Auto Save
Locate
File Group
Vert:0 Hriz:0 Scale: 1
Sample Area 1.5
Gamma 1.4
Light Source D65 (Std)