Service manual

6 (2890) A
CHECK LIST
3) Select the blank area (A) and click the Prescan button and confirm if each RGB value is 200
"30.
4) Click on the Manual focus button and move the mouse pointer to the manual focus point
(B), then drag the focus meter slider until the black and white lines are at their longest.
CAUTION:
Drag the slider from the left to the right.
5) Confirm that the image is selected entirely, and click the Scan button to start the final
scan.
6) Save the image as .BMP file.
CAUTION:
Chart scanning time is depending on the system configurations of the computer.
Measurement
1) Select Start > Program > DPEV > GEOM.
2) Click Setup > Measure and set the preference as below.
Measuring condition
Size Auto Detect
Resolution 5400 dpi
Chart Size 135
MTF 20/30/40
Measure item Check all
Data Out Auto Save
Pasted MTF-Data 40
Click the Profile “New” and input a profile
name, and then click the Save button.
(The setting will be effective from the next
measurement.)
RGB value should be 200!30
A
B
Manual focus Point