Service manual

(2890) A 3
CHECK LIST
FUNCTION
Power Switch
ON Before starting the driver, the indicator blinks.
At using the driver software, the indicator lamp glows or blinks accordingly as
below.
Lamp Condition
Glowing Normal except for the following.
Blinking slowly at 1Hz Mechanical drive (setup)
Blinking fast at 8Hz Error
OFF The indicator lamp turns off.
PC Interface
USB 2.0 / 1.1 or IEEE1394
Eject button
When the scanner is not operating (stand-by), pressing the Eject button ejects
the holder immediately.
Quick Scan button
When the scanner is not operating (stand-by), pressing the Quick scan button
launched desired application software.
In default setting, DiMAGE Scan Launcher starts.
DiMAGE Scan Launcher enables to select the application which starts when
pressing the Quick Scan button.
If the batch scan utility is selected, the scanner starts scanning.
Manual focus dial
When the Manual focus dial is selected in the preferences window, manual
focusing can be used on any point in the preview image.
While selecting the Manual focus dial, the Autofocus at scan is disabled.
Index Scan
Displays index in high speed or high quality as set in the preferences.
Prescan
Scans selected frames and displays on the prescan tab window.
Scan
Scans a selected frame and saves or export the image.
When selecting multiple images, scans them sequentially. (slide: max.4 frames/
film strip: max.6 frames)